| range of product | Modicon Premium Automation platform | 
|---|---|
| product or component type | Discrete output module | 
| discrete output number | 16 | 
| discrete output type | Relay not protected | 
| discrete output voltage | 12…24 V DC conforming to EN/IEC 61131-2 10…34 V 24…240 V AC conforming to EN/IEC 61131-2 20…264 V  | 
| [Ith] conventional free air thermal current | 3 A | 
|---|---|
| response time | < 10 ms (deactivation) < 8 ms (activation)  | 
| contacts type and composition | 1 NO | 
| output overvoltage protection | DC inductive, by discharge diode on each preactuator AC inductive, by RC circuit MOV (ZNO) on each preactuator  | 
| output overload protection | 1 external fuse per channel or group of channel fast blow | 
| short-circuit protection | 1 external fuse per channel or group of channel fast blow | 
| isalotion resistance | > 10 MOhm 500 V | 
| power dissipation | (0.25 W + 0.2 W x No of outputs at state 1) | 
| electrical durability | 1000000 cycles DC-12 24 W 24 V resistive 1000000 cycles DC-3 24 W 24 V inductive 2000000 cycles DC-3 10 W 24 V inductive 300000 cycles DC-12 40 W 24 V resistive 100000 cycles AC-14 220 VA 220 V inductive 100000 cycles AC-15 220 VA 220 V inductive 1000000 cycles AC-12 110 VA 110 V resistive 1000000 cycles AC-12 220 VA 220 V resistive 1000000 cycles AC-12 50 VA 48 V resistive 1000000 cycles AC-14 110 VA 220 V inductive 1000000 cycles AC-15 110 VA 220 V inductive 150000 cycles AC-14 110 VA 110 V inductive 150000 cycles AC-15 110 VA 110 V inductive 1500000 cycles AC-14 50 VA 110 V inductive 1500000 cycles AC-15 50 VA 110 V inductive 2000000 cycles AC-14 24 VA 48 V inductive 2000000 cycles AC-15 24 VA 48 V inductive 3000000 cycles AC-14 50 VA 220 V inductive 3000000 cycles AC-15 50 VA 220 V inductive 500000 cycles AC-12 110 VA 48 V resistive 500000 cycles AC-12 220 VA 110 V resistive 500000 cycles AC-14 24 VA 24 V inductive 500000 cycles AC-15 24 VA 24 V inductive 5000000 cycles AC-14 10 VA 110 V inductive 5000000 cycles AC-14 10 VA 220 V inductive 5000000 cycles AC-14 10 VA 48 V inductive 5000000 cycles AC-15 10 VA 110 V inductive 5000000 cycles AC-15 10 VA 220 V inductive 5000000 cycles AC-15 10 VA 48 V inductive 700000 cycles AC-12 50 VA 24 V resistive  | 
| marking | CE | 
| electrical connection | Screw terminal block | 
| current consumption | 135 mA at 24 V DC rack 80 mA at 5 V DC  | 
| module format | Standard | 
| net weight | 0.38 kg | 
| dielectric strength | 2000 V 50/60 Hz 60 s | 
|---|---|
| standards | 73/23/EEC IEC 61131-2 UL 508 CSA C22.2 No 213 Class I Division 2 Group B 92/31/EEC 89/336/EEC CSA C22.2 No 213 Class I Division 2 Group C CSA C22.2 No 213 Class I Division 2 Group A CSA C22.2 No 142 CSA C22.2 No 213 Class I Division 2 Group D 93/68/EEC  | 
| product certifications | BV RINA LR ABS RMRS GL DNV  | 
| ambient air temperature for operation | 0…60 °C | 
| ambient air temperature for storage | -25…70 °C | 
| relative humidity | 10…95 % without condensation for operation 5…95 % without condensation for storage  | 
| operating altitude | 0…2000 m | 
| protective treatment | TC | 
| IP degree of protection | IP20 | 
| pollution degree | 2 | 
| Unit Type of Package 1 | PCE | 
|---|---|
| Number of Units in Package 1 | 1 | 
| Package 1 Weight | 482.0 g | 
| Package 1 Height | 5.5 cm | 
| Package 1 width | 18.0 cm | 
| Package 1 Length | 26.0 cm | 
| Unit Type of Package 2 | S03 | 
| Number of Units in Package 2 | 8 | 
| Package 2 Weight | 4.371 kg | 
| Package 2 Height | 30.0 cm | 
| Package 2 width | 30.0 cm | 
| Package 2 Length | 40.0 cm | 