Description
| Model: | BMXDRA1605 |
| range of product |
Modicon X80
|
|
|---|---|---|
| product or component type |
Discrete output module
|
|
| discrete output number |
16 conforming to EN/IEC 61131-2
|
|
| discrete output type |
Relay
|
|
| discrete output voltage |
24 V 19…30 V DC
240 V 19…264 V AC |
| [Ith] conventional free air thermal current |
2 A
|
|
|---|---|---|
| insulation resistance |
> 10 MOhm 500 V DC
|
|
| power dissipation in W |
3 W
|
|
| response time on output |
< 8 ms activation
< 10 ms deactivation |
|
| typical current consumption |
79 mA at 3.3 V DC
|
|
| MTBF reliability |
1357810 H
|
|
| output overload protection |
Use 1 fast blow fuse per channel or group of channel
|
|
| output overvoltage protection |
Use discharge diode on each output DC
Use RC circuit on each output AC Use ZNO surge limiter on each output AC |
|
| output short-circuit protection |
Use 1 fast blow fuse per channel or group of channel
|
|
| minimum switching current |
1 mA 5 V DC
|
|
| electrical durability |
AC-15: 100000 cycles at 240 VA 200 V (load factor 0.7)
AC-15: 100000 cycles at 120 VA 200 V (load factor 0.35) AC-12: 100000 cycles at 200 VA 100 V AC-12: 100000 cycles at 80 VA 48 V AC-12: 100000 cycles at 50 VA 24 V AC-15: 100000 cycles at 120 VA 100 V AC-15: 100000 cycles at 120 VA 24 V AC-15: 100000 cycles at 120 VA 48 V DC-12: 100000 cycles at 24 W 24 V DC-13: 100000 cycles at 10 W 24 V DC-13: 100000 cycles at 10 W 48 V AC-15: 300000 cycles at 72 VA 200 V (load factor 0.7) AC-15: 300000 cycles at 36 VA 200 V (load factor 0.35) AC-12: 300000 cycles at 200 VA 200 V AC-12: 300000 cycles at 80 VA 100 V AC-12: 300000 cycles at 50 VA 48 V AC-15: 300000 cycles at 36 VA 100 V AC-15: 300000 cycles at 72 VA 100 V AC-15: 300000 cycles at 36 VA 48 V AC-15: 300000 cycles at 72 VA 48 V AC-15: 300000 cycles at 36 VA 24 V AC-15: 300000 cycles at 72 VA 24 V DC-13: 300000 cycles at 3 W 24 V DC-13: 300000 cycles at 3 W 48 V DC-13: 7000 cycles at 24 W 24 V DC-13: 7000 cycles at 24 W 48 V DC-12: 50000 cycles at 24 W 48 V |
|
| status LED |
1 LED (green)RUN
1 LED per channel (green)channel diagnostic 1 LED (red)ERR 1 LED (red)I/O |
|
| net weight |
0.15 kg
|
| IP degree of protection |
IP20
|
|
|---|---|---|
| dielectric strength |
2000 V AC at 50/60 Hz 1 min
|
|
| vibration resistance |
3 gn
|
|
| shock resistance |
30 gn
|
|
| ambient air temperature for storage |
-40…85 °C
|
|
| ambient air temperature for operation |
0…60 °C
|
|
| relative humidity |
5…95 % at 55 °C without condensation
|
|
| operating altitude |
0…2000 m
2000…5000 m with derating factor |
| Unit Type of Package 1 |
PCE
|
|
|---|---|---|
| Number of Units in Package 1 |
1
|
|
| Package 1 Weight |
187 g
|
|
| Package 1 Height |
5.5 cm
|
|
| Package 1 width |
11 cm
|
|
| Package 1 Length |
11.5 cm
|
|
| Unit Type of Package 2 |
S02
|
|
| Number of Units in Package 2 |
15
|
|
| Package 2 Weight |
3.144 kg
|
|
| Package 2 Height |
15 cm
|
|
| Package 2 width |
30 cm
|
|
| Package 2 Length |
40 cm
|
| Sustainable offer status |
Green Premium product
|
|
|---|---|---|
| REACh Regulation |
REACh Declaration
|
|
| REACh free of SVHC |
Yes
|
|
| EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
| Mercury free |
Yes
|
|
| RoHS exemption information |
Yes
|
|
| China RoHS Regulation |
China RoHS declaration
|
|
| Environmental Disclosure |
Product Environmental Profile
|
|
| Circularity Profile |
End of Life Information
|
|
| WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|