| range of product | Modicon STB distributed I/O solution |
|---|---|
| product or component type | Standard analog input kit |
| kit composition | STBART0200 module STBXTS1100, 6-terminal screw type connector STBXBA1000 base STBXTS2100, 6-terminal spring clamp connector |
| analogue input type | Voltage +/- 80 mV Temperature probe -100…+260 °C Cu 10 2, 3 or 4 wires IEC Temperature probe -100…+450 °C Pt 100 2, 3 or 4 wires US/JIS Temperature probe -100…+450 °C Pt 1000 2, 3 or 4 wires US/JIS Temperature probe -200…+850 °C Pt 100 2, 3 or 4 wires IEC Temperature probe -200…+850 °C Pt 1000 2, 3 or 4 wires IEC Temperature probe -60…+180 °C Ni 100 2, 3 or 4 wires IEC Temperature probe -60…+180 °C Ni 1000 2, 3 or 4 wires IEC Thermocouple +130…+1820 °C thermocouple B Thermocouple -200…+760 °C thermocouple J Thermocouple -270…+1000 °C thermocouple E Thermocouple -270…+1370 °C thermocouple K Thermocouple -270…+400 °C thermocouple T Thermocouple -50…+1665 °C thermocouple R Thermocouple -50…+1665 °C thermocouple S |
| analogue input number | 2 |
| analogue input resolution | 15 bits + sign |
| type of filter | Single low pass input filter 25 Hz |
| absolute maximum input | +/- 7.5 V DC |
|---|---|
| cold swapping | Yes |
| hot swapping fallback | Yes for standard NIMs |
| fallback status | State 0 basic NIMs User configurable standard NIMs |
| data format | EN 61131-2 IEC 61131-2 |
| input impedance | 10 MOhm +/- 80 mV |
| maximum supply current for sensors | 100 mA per input channels |
| protection type | Short-circuit protection |
| absolute accuracy error | +/- 0.1 % of full scale 25 °C internal +/- 0.15 % of full scale 25 °C external |
| insulation between channels and logic bus | 1500 V for 1 minute |
| addressing requirement | 1 word for cold-junction compensation 2 input words |
| product compatibility | Mounting base STBXBA1000 Power distribution module STBPDT3100/3105 |
| [Us] rated supply voltage | 24 V DC |
| supply | Power distribution module |
| current consumption | 30 mA at 5 V DC for logic bus |
| measurement resolution | 0.01 mV voltage 0.1 °C or 0.1 °F temperature probe 0.1 °C or 0.1 °F thermocouple |
| conversion time | 150 ms voltage 60 Hz 170 ms voltage 50 Hz 180 ms temperature probe 60 Hz 2 or 4 wires 200 ms temperature probe 50 Hz 2 or 4 wires 210 ms thermocouple with internal cold-junction compensation 60 Hz 230 ms thermocouple with internal cold-junction compensation 50 Hz 300 ms temperature probe 60 Hz 3 wires 340 ms temperature probe 50 Hz 3 wires 360 ms thermocouple with external cold-junction compensation 60 Hz 400 ms thermocouple with external cold-junction compensation 50 Hz |
| maximum wiring resistance | 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires 50 Ohm Cu 10 IEC/US/JIS 4 wires 50 Ohm Ni 100 IEC/US/JIS 4 wires 50 Ohm Pt 100 IEC/US/JIS 4 wires 500 Ohm Ni 1000 IEC/US/JIS 4 wires 500 Ohm Pt 1000 IEC/US/JIS 4 wires |
| measurement accuracy | +/- 1 °C Ni 100 25 °C external +/- 1 °C Ni 100 25 °C internal +/- 1 °C Ni 1000 25 °C external +/- 1 °C Ni 1000 25 °C internal +/- 1 °C Pt 100 25 °C internal +/- 1 °C Pt 1000 25 °C internal +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C +/- 2 °C Pt 100 25 °C external +/- 2 °C Pt 1000 25 °C external +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C +/- 4 °C Cu 10 25 °C external +/- 4 °C Cu 10 25 °C internal +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C |
| marking | CE |
| overvoltage category | II |
| status LED | 1 LED (green) module status (RDY) 1 LED (red) module error (ERR) |
| product certifications | UL FM Class 1 Division 2 CSA ATEX Cat 3G C-Tick |
|---|---|
| pollution degree | 2 conforming to IEC 60664-1 |
| operating altitude | <= 2000 m |
| IP degree of protection | IP20 conforming to EN 61131-2 class 1 |
| ambient air temperature for operation | 0…70 °C |
| ambient air temperature for operation | 32…140 °F without derating |
| ambient air temperature for storage | -40…85 °C without derating |
| ambient air temperature for storage | -40…185 °F without derating |
| relative humidity | 95 % at 60 °C without condensation |
| vibration resistance | +/-0.35 mm at 10…58 Hz 3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail 5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail |
| shock resistance | 30 gn for 11 ms conforming to IEC 88 reference 2-27 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Weight | 136.0 g |
| Package 1 Height | 2.5 cm |
| Package 1 width | 8.0 cm |
| Package 1 Length | 13.0 cm |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 42 |
| Package 2 Weight | 6.1 kg |
| Package 2 Height | 15.0 cm |
| Package 2 width | 30.0 cm |
| Package 2 Length | 40.0 cm |