Sale!

LC1D40AU7

Original price was: $ 78.00.Current price is: $ 60.00.

In stock

Category:

Description

Description

 

Main
RANGE TeSys
TeSys Deca
RANGE OF PRODUCT TeSys D
TeSys Deca
PRODUCT OR COMPONENT TYPE Contactor
DEVICE SHORT NAME LC1D
CONTACTOR APPLICATION Motor control
Resistive load
UTILISATION CATEGORY AC-4
AC-1
AC-3
AC-3e
POLES DESCRIPTION 3P
[UE] RATED OPERATIONAL VOLTAGE Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[IE] RATED OPERATIONAL CURRENT 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[UC] CONTROL CIRCUIT VOLTAGE 240 V AC 50/60 Hz
Complementary
MOTOR POWER KW 18.5 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 220…230 V AC 50/60 Hz (AC-3)
22 kW at 415…440 V AC 50/60 Hz (AC-3)
22 kW at 500 V AC 50/60 Hz (AC-3)
30 kW at 660…690 V AC 50/60 Hz (AC-3)
9 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 220…230 V AC 50/60 Hz (AC-3e)
22 kW at 415…440 V AC 50/60 Hz (AC-3e)
22 kW at 500 V AC 50/60 Hz (AC-3e)
30 kW at 660…690 V AC 50/60 Hz (AC-3e)
MOTOR POWER HP 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 115 V AC 50/60 Hz for 1 phase motors
30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
COMPATIBILITY CODE LC1D
POLE CONTACT COMPOSITION 3 NO
CONTACT COMPATIBILITY M2
PROTECTIVE COVER With
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
IRMS RATED MAKING CAPACITY 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
RATED BREAKING CAPACITY 800 A at 440 V for power circuit conforming to IEC 60947
[ICW] RATED SHORT-TIME WITHSTAND CURRENT 320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
ASSOCIATED FUSE RATING 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
AVERAGE IMPEDANCE 1.5 mOhm – Ith 60 A 50 Hz for power circuit
POWER DISSIPATION PER POLE 2.4 W AC-3
5.4 W AC-1
2.4 W AC-3e
[UI] RATED INSULATION VOLTAGE Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
OVERVOLTAGE CATEGORY III
POLLUTION DEGREE 3
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE 6 kV conforming to IEC 60947
SAFETY RELIABILITY LEVEL B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
MECHANICAL DURABILITY 6 Mcycles
ELECTRICAL DURABILITY 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.5 Mcycles 40 A AC-3e at Ue <= 440 V
CONTROL CIRCUIT TYPE AC at 50/60 Hz
COIL TECHNOLOGY Without built-in suppressor module
CONTROL CIRCUIT VOLTAGE LIMITS 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
INRUSH POWER IN VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
HOLD-IN POWER CONSUMPTION IN VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
MAXIMUM OPERATING RATE 3600 cyc/h 60 °C
TIGHTENING TORQUE Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
AUXILIARY CONTACT COMPOSITION 1 NO + 1 NC
AUXILIARY CONTACTS TYPE Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
SIGNALLING CIRCUIT FREQUENCY 25…400 Hz
MINIMUM SWITCHING VOLTAGE 17 V for signalling circuit
MINIMUM SWITCHING CURRENT 5 mA for signalling circuit
INSULATION RESISTANCE > 10 MOhm for signalling circuit
NON-OVERLAP TIME 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
MOUNTING SUPPORT Plate
Rail
Environment
STANDARDS CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
PRODUCT CERTIFICATIONS CSA
CCC
UL
GOST
IP DEGREE OF PROTECTION IP20 front face conforming to IEC 60529
CLIMATIC WITHSTAND Conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
OPERATING ALTITUDE 0…3000 m
FIRE RESISTANCE 850 °C conforming to IEC 60695-2-1
FLAME RETARDANCE V1 conforming to UL 94
HEIGHT 122 mm
WIDTH 55 mm
DEPTH 120 mm
NET WEIGHT 0.85 kg
Packing Units
UNIT TYPE OF PACKAGE 1 PCE
NUMBER OF UNITS IN PACKAGE 1 1
PACKAGE 1 HEIGHT 6.2 cm
PACKAGE 1 WIDTH 13.7 cm
PACKAGE 1 LENGTH 15.5 cm
PACKAGE 1 WEIGHT 927.0 g
UNIT TYPE OF PACKAGE 2 S02
NUMBER OF UNITS IN PACKAGE 2 10
PACKAGE 2 HEIGHT 15.0 cm
PACKAGE 2 WIDTH 30.0 cm
PACKAGE 2 LENGTH 40.0 cm
PACKAGE 2 WEIGHT 9.969 kg