RANGE | TeSys TeSys Deca |
---|---|
RANGE OF PRODUCT | TeSys D TeSys Deca |
PRODUCT OR COMPONENT TYPE | Contactor |
DEVICE SHORT NAME | LC1D |
CONTACTOR APPLICATION | Motor control Resistive load |
UTILISATION CATEGORY | AC-4 AC-1 AC-3 AC-3e |
POLES DESCRIPTION | 3P |
[UE] RATED OPERATIONAL VOLTAGE | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
[IE] RATED OPERATIONAL CURRENT | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
[UC] CONTROL CIRCUIT VOLTAGE | 240 V AC 50/60 Hz |
MOTOR POWER KW | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415…440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380…400 V AC 50/60 Hz (AC-3e) 11 kW at 220…230 V AC 50/60 Hz (AC-3e) 22 kW at 415…440 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 30 kW at 660…690 V AC 50/60 Hz (AC-3e) |
---|---|
MOTOR POWER HP | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
COMPATIBILITY CODE | LC1D |
POLE CONTACT COMPOSITION | 3 NO |
CONTACT COMPATIBILITY | M2 |
PROTECTIVE COVER | With |
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
IRMS RATED MAKING CAPACITY | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
RATED BREAKING CAPACITY | 800 A at 440 V for power circuit conforming to IEC 60947 |
[ICW] RATED SHORT-TIME WITHSTAND CURRENT | 320 A 40 °C – 10 s for power circuit 720 A 40 °C – 1 s for power circuit 72 A 40 °C – 10 min for power circuit 165 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
ASSOCIATED FUSE RATING | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit |
AVERAGE IMPEDANCE | 1.5 mOhm – Ith 60 A 50 Hz for power circuit |
POWER DISSIPATION PER POLE | 2.4 W AC-3 5.4 W AC-1 2.4 W AC-3e |
[UI] RATED INSULATION VOLTAGE | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
OVERVOLTAGE CATEGORY | III |
POLLUTION DEGREE | 3 |
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE | 6 kV conforming to IEC 60947 |
SAFETY RELIABILITY LEVEL | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
MECHANICAL DURABILITY | 6 Mcycles |
ELECTRICAL DURABILITY | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V 1.5 Mcycles 40 A AC-3e at Ue <= 440 V |
CONTROL CIRCUIT TYPE | AC at 50/60 Hz |
COIL TECHNOLOGY | Without built-in suppressor module |
CONTROL CIRCUIT VOLTAGE LIMITS | 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz 1…1.1 Uc (60…70 °C):operational AC 50/60 Hz |
INRUSH POWER IN VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
HOLD-IN POWER CONSUMPTION IN VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
MAXIMUM OPERATING RATE | 3600 cyc/h 60 °C |
TIGHTENING TORQUE | Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
AUXILIARY CONTACT COMPOSITION | 1 NO + 1 NC |
AUXILIARY CONTACTS TYPE | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
SIGNALLING CIRCUIT FREQUENCY | 25…400 Hz |
MINIMUM SWITCHING VOLTAGE | 17 V for signalling circuit |
MINIMUM SWITCHING CURRENT | 5 mA for signalling circuit |
INSULATION RESISTANCE | > 10 MOhm for signalling circuit |
NON-OVERLAP TIME | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
MOUNTING SUPPORT | Plate Rail |
STANDARDS | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
---|---|
PRODUCT CERTIFICATIONS | CSA CCC UL GOST |
IP DEGREE OF PROTECTION | IP20 front face conforming to IEC 60529 |
CLIMATIC WITHSTAND | Conforming to IACS E10 conforming to IEC 60947-1 Annex Q category D |
OPERATING ALTITUDE | 0…3000 m |
FIRE RESISTANCE | 850 °C conforming to IEC 60695-2-1 |
FLAME RETARDANCE | V1 conforming to UL 94 |
HEIGHT | 122 mm |
WIDTH | 55 mm |
DEPTH | 120 mm |
NET WEIGHT | 0.85 kg |
UNIT TYPE OF PACKAGE 1 | PCE |
---|---|
NUMBER OF UNITS IN PACKAGE 1 | 1 |
PACKAGE 1 HEIGHT | 6.2 cm |
PACKAGE 1 WIDTH | 13.7 cm |
PACKAGE 1 LENGTH | 15.5 cm |
PACKAGE 1 WEIGHT | 927.0 g |
UNIT TYPE OF PACKAGE 2 | S02 |
NUMBER OF UNITS IN PACKAGE 2 | 10 |
PACKAGE 2 HEIGHT | 15.0 cm |
PACKAGE 2 WIDTH | 30.0 cm |
PACKAGE 2 LENGTH | 40.0 cm |
PACKAGE 2 WEIGHT | 9.969 kg |