Sale!

LC1D40ABNE

$ 75.00

In stock

Category:

Description

Description

Main
RANGE TeSys
TeSys Deca
RANGE OF PRODUCT TeSys D
TeSys Deca
PRODUCT OR COMPONENT TYPE Contactor
DEVICE SHORT NAME LC1D
CONTACTOR APPLICATION Resistive load
Motor control
UTILISATION CATEGORY AC-3
AC-1
AC-3e
POLES DESCRIPTION 3P
[UE] RATED OPERATIONAL VOLTAGE Power circuit: <= 690 V AC 25…400 Hz
[IE] RATED OPERATIONAL CURRENT 60 A (at <60 °C) at <= 440 V AC-1 for power circuit
40 A (at <60 °C) at <= 440 V AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC-3e for power circuit
[UC] CONTROL CIRCUIT VOLTAGE 24…60 V AC 50/60 Hz
24…60 V DC
Complementary
MOTOR POWER KW 11 kW at 220…230 V AC 50 Hz (AC-3)
18.5 kW at 380…400 V AC 50 Hz (AC-3)
22 kW at 415 V AC 50 Hz (AC-3)
22 kW at 440 V AC 50 Hz (AC-3)
22 kW at 500 V AC 50 Hz (AC-3)
30 kW at 660…690 V AC 50 Hz (AC-3)
11 kW at 220…230 V AC 50 Hz (AC-3e)
18.5 kW at 380…400 V AC 50 Hz (AC-3e)
22 kW at 415 V AC 50 Hz (AC-3e)
22 kW at 440 V AC 50 Hz (AC-3e)
22 kW at 500 V AC 50 Hz (AC-3e)
30 kW at 660…690 V AC 50 Hz (AC-3e)
MOTOR POWER HP 3 hp at 115 V AC 60 Hz for 1 phase motors
5 hp at 230/240 V AC 60 Hz for 1 phase motors
10 hp at 200/208 V AC 60 Hz for 3 phases motors
10 hp at 230/240 V AC 60 Hz for 3 phases motors
30 hp at 460/480 V AC 60 Hz for 3 phases motors
30 hp at 575/600 V AC 60 Hz for 3 phases motors
COMPATIBILITY CODE LC1D
POLE CONTACT COMPOSITION 3 NO
PROTECTIVE COVER With
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT 60 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuit
IRMS RATED MAKING CAPACITY 800 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
RATED BREAKING CAPACITY 800 A at 440 V for power circuit conforming to IEC 60947
[ICW] RATED SHORT-TIME WITHSTAND CURRENT 72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
ASSOCIATED FUSE RATING 80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
AVERAGE IMPEDANCE 1.5 mOhm – Ith 60 A 50 Hz for power circuit
POWER DISSIPATION PER POLE 5.4 W AC-1
2.4 W AC-3
2.4 W AC-3e
[UI] RATED INSULATION VOLTAGE Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
OVERVOLTAGE CATEGORY III
POLLUTION DEGREE 3
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE 6 kV conforming to IEC 60947
SAFETY RELIABILITY LEVEL B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
MECHANICAL DURABILITY 6 Mcycles
CONTROL CIRCUIT TYPE AC/DC at 50/60 Hz AC/DC electronic
COIL TECHNOLOGY Built-in bidirectional peak limiting
CONTROL CIRCUIT VOLTAGE LIMITS <= 0.1 Uc (-40…70 °C):drop-out AC/DC
0.85…1.1 Uc (-40…60 °C):operational AC
0.8…1.1 Uc (-40…60 °C):operational DC
1…1.1 Uc (60…70 °C):operational AC/DC
OPERATING TIME 55…65 ms closing
20…120 ms opening (date code >= 17221)
20…80 ms opening (date code >= 18011)
MAXIMUM OPERATING RATE 3600 cyc/h 60 °C
TIGHTENING TORQUE Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Power circuit: 2.5 N.m – on lugs-ring terminals – with screwdriver pozidriv No 2 M4
Control circuit: 1.7 N.m – on lugs-ring terminals – with screwdriver pozidriv No 2 M3.5
AUXILIARY CONTACT COMPOSITION 1 NO + 1 NC
AUXILIARY CONTACTS TYPE Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
SIGNALLING CIRCUIT FREQUENCY 25…400 Hz
MINIMUM SWITCHING VOLTAGE 17 V for signalling circuit
MINIMUM SWITCHING CURRENT 5 mA for signalling circuit
INSULATION RESISTANCE > 10 MOhm for signalling circuit
NON-OVERLAP TIME 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
MOUNTING SUPPORT Plate
Rail
Environment
IP DEGREE OF PROTECTION IP20 front face conforming to IEC 60529
CLIMATIC WITHSTAND Conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
OPERATING ALTITUDE 0…3000 m
FIRE RESISTANCE 850 °C conforming to IEC 60695-2-1
FLAME RETARDANCE V1 conforming to UL 94
HEIGHT 122 mm
WIDTH 55 mm
DEPTH 120 mm
NET WEIGHT 0.992 kg
Packing Units
UNIT TYPE OF PACKAGE 1 PCE
NUMBER OF UNITS IN PACKAGE 1 1
PACKAGE 1 HEIGHT 6.2 cm
PACKAGE 1 WIDTH 13.7 cm
PACKAGE 1 LENGTH 15.2 cm
PACKAGE 1 WEIGHT 1.05 kg
UNIT TYPE OF PACKAGE 2 S02
NUMBER OF UNITS IN PACKAGE 2 9
PACKAGE 2 HEIGHT 15 cm
PACKAGE 2 WIDTH 30 cm
PACKAGE 2 LENGTH 40 cm
PACKAGE 2 WEIGHT 9.75 kg