Sale!

LC1D25U7

Original price was: $ 39.00.Current price is: $ 30.00.

In stock

Category:

Description

Description

Main
RANGE OF PRODUCT TeSys Deca
PRODUCT OR COMPONENT TYPE Contactor
DEVICE SHORT NAME LC1D
CONTACTOR APPLICATION Motor control
Resistive load
UTILISATION CATEGORY AC-3
AC-1
AC-3e
POLES DESCRIPTION 3P
[UE] RATED OPERATIONAL VOLTAGE Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[IE] RATED OPERATIONAL CURRENT 25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[UC] CONTROL CIRCUIT VOLTAGE 240 V AC 50/60 Hz
Complementary
MOTOR POWER KW 5.5 kW at 220…230 V AC 50/60 Hz (AC-3)
11 kW at 380…400 V AC 50/60 Hz (AC-3)
11 kW at 415…440 V AC 50/60 Hz (AC-3)
15 kW at 500 V AC 50/60 Hz (AC-3)
15 kW at 660…690 V AC 50/60 Hz (AC-3)
5.5 kW at 400 V AC 50/60 Hz (AC-4)
5.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
11 kW at 380…400 V AC 50/60 Hz (AC-3e)
11 kW at 415…440 V AC 50/60 Hz (AC-3e)
15 kW at 500 V AC 50/60 Hz (AC-3e)
15 kW at 660…690 V AC 50/60 Hz (AC-3e)
MOTOR POWER HP 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
COMPATIBILITY CODE LC1D
POLE CONTACT COMPOSITION 3 NO
CONTACT COMPATIBILITY M2
PROTECTIVE COVER With
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT 10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit
IRMS RATED MAKING CAPACITY 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
RATED BREAKING CAPACITY 450 A at 440 V for power circuit conforming to IEC 60947
[ICW] RATED SHORT-TIME WITHSTAND CURRENT 240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
ASSOCIATED FUSE RATING 10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit
AVERAGE IMPEDANCE 2 mOhm – Ith 40 A 50 Hz for power circuit
POWER DISSIPATION PER POLE 3.2 W AC-1
1.25 W AC-3
1.25 W AC-3e
[UI] RATED INSULATION VOLTAGE Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
OVERVOLTAGE CATEGORY III
POLLUTION DEGREE 3
[UIMP] RATED IMPULSE WITHSTAND VOLTAGE 6 kV conforming to IEC 60947
SAFETY RELIABILITY LEVEL B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
MECHANICAL DURABILITY 15 Mcycles
ELECTRICAL DURABILITY 1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
1.65 Mcycles 25 A AC-3e at Ue <= 440 V
CONTROL CIRCUIT TYPE AC at 50/60 Hz
COIL TECHNOLOGY Without built-in suppressor module
CONTROL CIRCUIT VOLTAGE LIMITS 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
INRUSH POWER IN VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
HOLD-IN POWER CONSUMPTION IN VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
HEAT DISSIPATION 2…3 W at 50/60 Hz
OPERATING TIME 12…22 ms closing
4…19 ms opening
MAXIMUM OPERATING RATE 3600 cyc/h 60 °C
CONNECTIONS – TERMINALS Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: solid without cable end
TIGHTENING TORQUE Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
AUXILIARY CONTACT COMPOSITION 1 NO + 1 NC
AUXILIARY CONTACTS TYPE Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
SIGNALLING CIRCUIT FREQUENCY 25…400 Hz
MINIMUM SWITCHING VOLTAGE 17 V for signalling circuit
MINIMUM SWITCHING CURRENT 5 mA for signalling circuit
INSULATION RESISTANCE > 10 MOhm for signalling circuit
NON-OVERLAP TIME 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
MOUNTING SUPPORT Rail
Plate
Environment
STANDARDS CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
PRODUCT CERTIFICATIONS RINA
CSA
BV
UL
CCC
LROS (Lloyds register of shipping)
DNV
GOST
GL
UKCA
IP DEGREE OF PROTECTION IP20 front face conforming to IEC 60529
PROTECTIVE TREATMENT TH conforming to IEC 60068-2-30
CLIMATIC WITHSTAND Conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
PERMISSIBLE AMBIENT AIR TEMPERATURE AROUND THE DEVICE -40…60 °C
60…70 °C with derating
OPERATING ALTITUDE 0…3000 m
FIRE RESISTANCE 850 °C conforming to IEC 60695-2-1
FLAME RETARDANCE V1 conforming to UL 94
MECHANICAL ROBUSTNESS Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
HEIGHT 85 mm
WIDTH 45 mm
DEPTH 92 mm
NET WEIGHT 0.37 kg
Packing Units
UNIT TYPE OF PACKAGE 1 PCE
NUMBER OF UNITS IN PACKAGE 1 1
PACKAGE 1 HEIGHT 5.0 cm
PACKAGE 1 WIDTH 9.2 cm
PACKAGE 1 LENGTH 11.2 cm
PACKAGE 1 WEIGHT 414.0 g
UNIT TYPE OF PACKAGE 2 S02
NUMBER OF UNITS IN PACKAGE 2 20
PACKAGE 2 HEIGHT 15.0 cm
PACKAGE 2 WIDTH 30.0 cm
PACKAGE 2 LENGTH 40.0 cm
PACKAGE 2 WEIGHT 8.715 kg
UNIT TYPE OF PACKAGE 3 P06
NUMBER OF UNITS IN PACKAGE 3 320
PACKAGE 3 HEIGHT 75.0 cm
PACKAGE 3 WIDTH 80.0 cm
PACKAGE 3 LENGTH 60.0 cm
PACKAGE 3 WEIGHT 147.94 kg