Description
Description
RANGE OF PRODUCT | Modicon X80 |
---|---|
PRODUCT OR COMPONENT TYPE | Relay discrete output module |
DISCRETE OUTPUT NUMBER | 8 conforming to EN/IEC 61131-2 |
DISCRETE OUTPUT LOGIC | Positive |
DISCRETE OUTPUT VOLTAGE | 24…240 V 19…264 V AC 24…125 V 5…150 V DC |
ELECTRICAL CONNECTION | 20 ways terminal block |
---|---|
NETWORK FREQUENCY | 50/60 Hz |
NETWORK FREQUENCY LIMITS | 47…63 Hz |
SENSOR POWER SUPPLY | 5…150 V 19…264 V |
[ITH] CONVENTIONAL FREE AIR THERMAL CURRENT | 3 A |
INSULATION RESISTANCE | > 10 MOhm 500 V DC |
POWER DISSIPATION IN W | 3.6 W |
RESPONSE TIME ON OUTPUT | <= 10 ms activation <= 13 ms deactivation |
TYPICAL CURRENT CONSUMPTION | 40 mA at 3.3 V DC 101 mA at 24 V DC |
MTBF RELIABILITY | 2683411 H |
PROTECTION TYPE | External short-circuit protection External overload protection External overvoltage protection, inductive AC network External overvoltage protection, inductive DC network |
OUTPUT OVERLOAD PROTECTION | Use 1 fast blow fuse per channel or group of channel |
OUTPUT OVERVOLTAGE PROTECTION | Use discharge diode on each output DC Use RC circuit on each output AC Use ZNO surge limiter on each output AC |
OUTPUT SHORT-CIRCUIT PROTECTION | Use 1 fast blow fuse per channel or group of channel |
MINIMUM SWITCHING CURRENT | 1 mA 5 V DC |
ELECTRICAL DURABILITY | AC-12: 200000 cycles at 48 VA 24 V at 0…60 °C AC-12: 300000 cycles at 48 VA 48 V at 0…60 °C AC-12: 150000 cycles at 96 VA 48 V at 0…60 °C AC-12: 300000 cycles at 110 VA 100…120 V at 0…60 °C AC-12: 150000 cycles at 220 VA 100…120 V at 0…60 °C AC-12: 300000 cycles at 220 VA 200…250 V at 0…60 °C AC-12: 150000 cycles at 500 VA 200…250 V at 0…60 °C AC-15: 700000 cycles at 10 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 24 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 200000 cycles at 48 VA 24 V at 0…60 °C (load factor 0.4) AC-15: 700000 cycles at 10 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 24 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 300000 cycles at 48 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 100000 cycles at 96 VA 48 V at 0…60 °C (load factor 0.4) AC-15: 1000000 cycles at 10 VA 100…120 V at 0…60 °C (load factor 0.4) AC-15: 300000 cycles at 50 VA 100…120 V at 0…60 °C (load factor 0.4) AC-15: 200000 cycles at 110 VA 100…120 V at 0…60 °C (load factor 0.4) AC-15: 70000 cycles at 220 VA 100…120 V at 0…60 °C (load factor 0.4) AC-15: 1000000 cycles at 10 VA 200…250 V at 0…60 °C (load factor 0.4) AC-15: 500000 cycles at 50 VA 200…250 V at 0…60 °C (load factor 0.4) AC-15: 200000 cycles at 110 VA 200…250 V at 0…60 °C (load factor 0.4) AC-15: 150000 cycles at 220 VA 200…250 V at 0…60 °C (load factor 0.4) DC-12: 200000 cycles at 24 W 24 V at 0…60 °C DC-12: 150000 cycles at 48 W 24 V at 0…60 °C DC-12: 150000 cycles at 40 W 48…60 V at 0…60 °C DC-12: 100000 cycles at 45 W 100…125 V at 0…60 °C DC-13: 100000 cycles at 10 W 24 V at 0…60 °C DC-13: 60000 cycles at 24 W 24 V at 0…60 °C DC-13: 40000 cycles at 48 W 24 V at 0…60 °C DC-13: 40000 cycles at 40 W 48…60 V at 0…60 °C DC-13: 100000 cycles at 15 W 100…125 V at 0…60 °C |
STATUS LED | 1 LED (green) RUN 1 LED per channel (green) channel diagnostic 1 LED (red) ERR 1 LED (red) I/O |
NET WEIGHT | 0.169 kg |
IP DEGREE OF PROTECTION | IP20 |
---|---|
DIELECTRIC STRENGTH | 1780 V AC at 50/60 Hz 1 min |
VIBRATION RESISTANCE | 3 gn |
SHOCK RESISTANCE | 30 gn |
AMBIENT AIR TEMPERATURE FOR STORAGE | -40…85 °C |
AMBIENT AIR TEMPERATURE FOR OPERATION | 0…60 °C |
RELATIVE HUMIDITY | 0…95 % at 60 °C without condensation |
OPERATING ALTITUDE | 0…2000 m 2000…5000 m with derating factor |
UNIT TYPE OF PACKAGE 1 | PCE |
---|---|
NUMBER OF UNITS IN PACKAGE 1 | 1 |
PACKAGE 1 HEIGHT | 5.5 cm |
PACKAGE 1 WIDTH | 11.0 cm |
PACKAGE 1 LENGTH | 11.5 cm |
PACKAGE 1 WEIGHT | 202.0 g |
UNIT TYPE OF PACKAGE 2 | S02 |
NUMBER OF UNITS IN PACKAGE 2 | 15 |
PACKAGE 2 HEIGHT | 15.0 cm |
PACKAGE 2 WIDTH | 30.0 cm |
PACKAGE 2 LENGTH | 40.0 cm |
PACKAGE 2 WEIGHT | 3.03 kg |