Description
soft starter for asynchronous motor, ATS48, 96 A, 208..690 V, 22..90 KW
range of product | Altistart 48 |
---|---|
product or component type | Soft starter |
product destination | Asynchronous motors |
product specific application | Heavy duty industry and pumps |
device short name | ATS48 |
power supply voltage | 208…690 V – 15…10 % |
motor power kW | 22 kW at 230 V for severe applications 30 kW at 230 V for standard applications 45 kW at 400 V for severe applications 45 kW at 440 V for severe applications 55 kW at 400 V for standard applications 55 kW at 440 V for standard applications 55 kW at 500 V for severe applications 55 kW at 525 V for severe applications 75 kW at 500 V for standard applications 75 kW at 525 V for standard applications 75 kW at 660 V for severe applications 75 kW at 690 V for severe applications 90 kW at 660 V for standard applications 90 kW at 690 V for standard applications |
motor power hp | 100 hp at 575 V for standard applications 25 hp at 208 V for severe applications 30 hp at 208 V for standard applications 30 hp at 230 V for severe applications 40 hp at 230 V for standard applications 60 hp at 460 V for severe applications 75 hp at 460 V for standard applications 75 hp at 575 V for severe applications |
power dissipation in W | 252 W for standard applications 322 W for standard applications |
utilisation category | AC-53A |
type of start | Start with torque control (current limited to 5 In) |
Icl nominal current | 110 A for connection in the motor supply line for standard applications 110 A for connection in the motor supply line for severe applications |
assembly style | With heat sink |
---|---|
function available | External bypass (optional) |
power supply frequency | 50…60 Hz – 5…5 % |
power supply frequency limits | 47.5…63 Hz |
device connection | In the motor supply line |
discrete output number | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
output absolute accuracy precision | +/- 5 % |
minimum switching current | 10 mA at 6 V DC for relay outputs |
maximum switching current | Logic output 0.2 A at 30 V DC Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms |
discrete input number | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input voltage | 24 V <= 30 V |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
starting current | 0.4…1.3 Icl adjustable |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
communication port protocol | Modbus |
connector type | 1 RJ45 |
communication data link | Serial |
physical interface | RS485 multidrop |
transmission rate | 4800, 9600 or 19200 bps |
max nodes number | 31 |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
marking | CE |
operating position | Vertical +/- 10 degree |
height | 290 mm |
width | 190 mm |
depth | 235 mm |
product weight | 8.3 kg |
Motor power range AC-3 | 15…25 kW at 200…240 V 3 phases 30…50 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases 55…100 kW at 480…500 V 3 phases |
motor starter type | Soft starter |
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
---|---|
standards | EN/IEC 60947-4-2 |
product certifications | GOST TCF CCC SEPRO NOM 117 C-Tick CSA UL DNV |
noise level | 58 dB |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
ambient air temperature for storage | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 10.657 kg |
Package 1 Height | 36.5 cm |
Package 1 width | 30.5 cm |
Package 1 Length | 40 cm |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 4 |
Package 2 Weight | 48.156 kg |
Package 2 Height | 77 cm |
Package 2 width | 80 cm |
Package 2 Length | 60 cm |
Sustainable offer status | Green Premium product |
---|---|
REACh Regulation | REACh Declaration |
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
|
Mercury free | Yes |
RoHS exemption information | Yes |
China RoHS Regulation | China RoHS declaration |
Environmental Disclosure | Product Environmental Profile |
Circularity Profile | End of Life Information |
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
California proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |