Sale!

140CPU31110 Used

Original price was: $ 3,055.00.Current price is: $ 2,350.00.

Unity processor Modicon Quantum – 548 kB – 66 MHz

In stock

Category: Tag:

Description

Unity processor Modicon Quantum – 548 kB – 66 MHz

Main
range of product Modicon Quantum automation platform
product or component type Unity processor
Complementary
clock frequency 66 MHz
number of slots 16
4
10
2
6
number of racks 2 – local rack(s)
number of distributed I/O station 63 station(s) – 1 rack(s) – 3 Modbus Plus network(s)
number of remote I/O station 31 – 2 rack(s) per S908 remote I/O
0 – 0 rack(s) per ethernet remote I/O
discrete I/O number Unlimited (27 slots max) – local
31744 inputs, 31744 outputs – remote
8000 inputs, 8000 outputs – distributed – per network Modbus Plus
analogue I/O number Unlimited (27 slots max) – local
500 inputs, 500 outputs – distributed – per network Modbus Plus
1984 inputs,1984 outputs – S908 remote I/O
application specific I/O High-speed interrupt inputs
Counter
Accurate time stamping
Serial link
number of optional modules 2 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
maximum number of connections 1 USB
2 AS-Interface – distributed
2 Ethernet TCP/IP – local
2 Modbus Plus – local
2 Modbus (RS232/485 Modbus/ASCII)
2 Profibus DP – local
4 AS-Interface – remote
integrated connection type 1 Modbus Plus with
2 Modbus with
checks Process control
memory description Internal RAM 548 kB
switch function Slide switch communication port : ASCII/RTU/Memory
Slide switch memory port/off
application structure 1 cyclic/periodic master task –
1 periodic fast task –
16 timer interrupt tasks –
64 I/O interrupt tasks –
64 interrupt tasks –
No auxiliary task –
execution time per instruction 0.1…0.27 µs floating points
0.1…0.27 µs on fixed-point arithmetic
0.12…0.585 µs Boolean
0.12…0.585 µs on word
number of instructions per ms 1.86 Kinst/ms 100 % Boolean
2.49 Kinst/ms 65 % Boolean and 35 % numerical
system overhead 0.2 ms for fast task
1 ms for master task
bus current requirement 1800 mA
local signalling 1 LED (green) for communications are active on the Modbus Plus port (Modbus Plus)
1 LED (green) for communications are active on the Modbus port (Modbus)
1 LED (green) for CPU has been started and is solving logic (RUN)
1 LED (green) for CPU has passed the power-up diagnostic tests (READY)
1 LED (orange) for write-protected memory (memory port)
1 LED (red) for battery needs replacing or is not present (BAT LOW)
1 LED (red) for communications error on the Modbus Plus port (ERROR A)
electrical connection 1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network
2 female connectors, connector type: SUB-D 9 for connecting to the Modbus bus
Environment
product certifications CSA
CE
UL
standards HazLoc
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 720 g
Package 1 Height 5 cm
Package 1 width 17 cm
Package 1 Length 31 cm
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Weight 5.97 kg
Package 2 Height 30 cm
Package 2 width 30 cm
Package 2 Length 40 cm